Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 45
Filter
1.
RGO (Porto Alegre) ; 71: e20230007, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1431164

ABSTRACT

ABSTRACT Objective: To evaluate the dimensional change of edentulous models made of high density laboratory silicones at different storagetimes. Methods: A metallic master model simulating an edentulous maxilla was used. The model had projections of 1.8 cm located in the regions of canines (A and B) and molars (C and D) allowing the linear measurement of distances AB, BC, CD, DA, AC and BD. A laboratory silicone mold was made for duplication of master model in the following materials (n = 10): G1: Zetalabor 85, G2: Titanium 95, G3: Platinum 95 and G4: Gypsum type III (control). The samples were photographed and measured using a software (Image J) at times T1 (baseline) and T2 (after one week of models fabrication). The data were statistically analyzed using Kruskal- Wallis and Dun non-parametric tests (α = 0.05). Results: The storage time influenced the behavior of the materials evaluated. All groups presented dimensional changes in both times and the group Tit95 presented the best results. Only Zet85 group showed a different behavior related to the region of the model. Conclusions: The high density laboratory silicones showed satisfactory results when compared to the gypsum group. Tit95 was the most stable material and it can be recommended as an edentulous model for total protheses.


RESUMO Objetivo: Avaliar a alteração dimensional de modelos edêntulos fabricados em silicone laboratorial de alta densidade em diferentes tempos de armazenagem. Métodos: Um modelo mestre metálico simulando uma maxila edêntula foi utilizado. O modelo possuía projeções oclusais de 1,8 cm localizadas nas regiões de caninos (A e B) e molares (C e D), permitindo a mensuração das distâncias lineares AB, BC, CD, DA, AC e BD. Um molde foi fabricado em silicone laboratorial para duplicação do modelo mestre com os seguintes materiais (n = 10): G1: Zetalabor 85, G2: Titanium 95, G3: Platinum 95 e G4: Gesso tipo III (controle). As amostras foram fotografadas e mensuradas com auxílio de um software (Image J) nos tempos T1 (baseline) e T2 (após uma semana de confecção). Os dados obtidos foram avaliados estatisticamente utilizando os testes não paramétricos de Kruskal- Wallis e Dunn (α = 0.05). Resultados: O tempo de armazenagem influenciou o comportamento dos materiais avaliados. Todos os grupos apresentaram alterações dimensionais em ambos os temos de avaliação e o G2 apresentou os melhores resultados. Apenas o grupo G1 mostrou alteração dimensional dependente da região mensurada. Conclusão: Silicones laboratoriais de alta densidade mostraram resultados satisfatórias de alteração dimensional quando comparados ao gesso tipo III. O material Titanium 95foi o mais estável e pode ser recomendado como alternativa para a confecção de modelos edêntulos.

2.
Rev. Bras. Psicoter. (Online) ; 24(2): 3-17, out. 2022.
Article in Portuguese | LILACS, INDEXPSI | ID: biblio-1412869

ABSTRACT

O presente estudo teve como objetivo reunir evidências de validade de construto, baseadas na estrutura interna, do Big Five Inventory-2-Short (BFI-2-S) para o contexto da segurança pública brasileira. Participaram do estudo 9.742 agentes da segurança pública de diferentes corporações de todas as unidades federativas do Brasil. A maioria dos participantes era do sexo masculino 80,1% (ƒ = 8.156), com idades entre 18 e 73 anos (M = 41,55; DP = 8,02) e com tempo de trabalho na corporação entre 1 e 45 anos (M = 14,51; DP = 8,46). Os agentes responderam ao teste de personalidade BFI-2-S e a um questionário sociodemográfico, por meio de questionário eletrônico. A amostra foi dividida aleatoriamente em duas subamostras para validação cruzada. Em ambas as subamostras foram realizadas análises fatoriais exploratórias que indicaram uma estrutura trifatorial da BFI-2-S, com índices de fidedignidade adequados. Foram identificados os fatores extroversão, neuroticismo e conscienciosidade. Os itens referentes aos fatores amabilidade e abertura à experiência não apresentaram cargas fatoriais satisfatórias. Apesar da estrutura fatorial ter sido divergente do modelo teoricamente proposto pelo instrumento, isto é, o modelo de cinco fatores, o BFI-2-S se mostrou como um instrumento adequado para a avaliação das dimensões de conscienciosidade, neuroticismo e extroversão em servidores da segurança pública brasileiros.(AU)


The present study aimed to gather evidence of construct validity, based on the internal structure, of the Big Five Inventory-2-Short (BFI-2-S) for the context of Brazilian public security. 10.885 public security agents from different police forces from all federal units in Brazil were recruited through an electronic questionnaire, most were male, 80.1% (ƒ = 8,156), aged between 18 and 73 years (M = 41.55; SD = 8.02), working in the organization between 1 and 45 years (M = 14.51; SD = 8.46). Agents completed the BFI-2-S personality test and a sociodemographic questionnaire. The responses obtained were split into two random subsamples and a cross-validation procedure was performed. Thus, in both subsamples Exploratory Factor Analysis was carried out, which indicated a structure composed of three factors, with adequate reliability. Despite differing from the model theoretically proposed by the instrument, the BFI-2-S proved to be an adequate instrument for assessing the dimensions of conscientiousness, emotional instability and extroversion in Brazilian police officers.(AU)


El presente estudio tuvo como objetivo recopilar evidencias de validez de constructo, con base en la estructura interna, del Big Five Inventory-2-Short (BFI-2-S) para el contexto de la seguridad pública brasileña. 10.885 agentes de seguridad pública de diferentes corporaciones de todas las unidades federales de Brasil, la mayoría eran hombres 80,1% (ƒ = 8.156), con edad entre 18 y 73 años (M = 41,55; SD = 8,02) y con tiempo de trabajo en la corporación entre 1 y 45 años (M = 14.51; SD = 8.46). Los agentes completaron el test de personalidad BFI-2-S y un cuestionario sociodemográfico a través de un cuestionario electrónico. Las respuestas obtenidas se dividieron en dos submuestras aleatorias y se realizó un procedimiento de validación cruzada. Así, en ambas submuestras se realizaron Análisis Factoriales Exploratorios, los cuales indicaron una estructura compuesta por tres factores, con índices de confiabilidad adecuados. A pesar de diferir del modelo propuesto teóricamente por el instrumento, el BFI-2-S demostró ser un instrumento adecuado para evaluar las dimensiones de escrupulosidad, inestabilidad y extroversión en policías brasileños.(AU)


Subject(s)
Psychometrics , Surveys and Questionnaires , Factor Analysis, Statistical
3.
CoDAS ; 34(1): e20200318, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1345823

ABSTRACT

ABSTRACT Purpose To evaluate the agreement among instruments of the quantitative evaluation of hard palate. Methods This cross-sectional study was performed with a sample of 30 children aged 6 to 11 from Santa Maria, Southern Brazil. The instruments for palate measurements evaluated were: digital caliper, used directly in the oral cavity and in plaster casts, Korkhaus tridimensional bow, used directly in the oral cavity and in plaster casts, and Dolphin Imaging Software used for measurements in cone-beam computed tomography (CBCT). The agreement among different instruments was evaluated using the Intraclass Correlation Coefficient (ICC). Results The means of all transversal dimensions obtained by cone-beam computed tomography were lower than those of the other instruments - the agreement values in the width between the canines and in the width between the first molars were lower when comparing the cone-beam computed tomography and the other instruments. In the width between the first and second premolars, all comparisons showed acceptable agreement values. Good concordance values were obtained when comparing the palate depth at the second premolar region when using a bow divider inside the oral cavity and in the cast. Conclusion Most instruments presented satisfactory agreement in the measurements related to the transverse plane of the hard palate. However, when the vertical plane was evaluated, only the bow divider applied to both cast and oral cavity presented ideal agreement.


RESUMO Objetivo Avaliar a concordância entre instrumentos de avaliação quantitativa do palato duro. Método Este estudo transversal foi realizado com uma amostra de 30 crianças de 6 a 11 anos de Santa Maria, sul do Brasil. Os instrumentos de medidas do palato avaliados foram: paquímetro digital, utilizado diretamente na cavidade oral e em modelos de gesso, arco tridimensional Korkhaus, usado diretamente na cavidade oral e em modelos de gesso, e Dolphin Imaging Software utilizado para medições em tomografia computadorizada de feixe cônico (CBCT). A concordância entre os diferentes instrumentos foi avaliada por meio do Coeficiente de Correlação Intraclasse (ICC). Resultados As médias de todas as dimensões transversais obtidas pela tomografia computadorizada de feixe cônico foram menores do que as dos outros instrumentos - os valores de concordância na largura entre os caninos e na largura entre os primeiros molares foram baixos na comparação entre a tomografia computadorizada de feixe cônico e os demais instrumentos. Na largura entre o primeiro e o segundo pré-molar, todas as comparações apresentaram valores de concordância aceitáveis. Valores de concordância aceitáveis também foram obtidos ao comparar a profundidade do palato na região do segundo pré-molar com o uso de um divisor de arco dentro da cavidade oral e no gesso. Conclusão A maioria dos instrumentos apresentou concordância satisfatória nas medidas relacionadas ao plano transverso do palato duro. Porém, quando avaliado o plano vertical, apenas o divisor de arco aplicado tanto no gesso quanto na cavidade oral apresentou concordância ideal.

4.
Dent. press endod ; 11(3): 40-45, Sept-Dec.2021. Tab, Ilus
Article in English | LILACS | ID: biblio-1379003

ABSTRACT

Objetivo: O objetivo desse artigo foi avaliar a precisão das porções milimetrada e calibradora das réguas endodônticas, e avaliar a regularidade da superfície dos orifícios calibradores. Métodos: A porção milimetrada das réguas Angelus, Maillefer, Maquira, Microdont e Prisma foi avaliada com paquímetro eletrônico digital. Os orifícios calibradores da Maillefer, Prisma e Angelus foram medidos com um projetor de perfil. A regularidade da superfície dos orifícios calibradores foi classificada em S1 ­ sem irregularidades ou S2 ­ com regularidades. A análise de precisão das porções milimetrada e calibradora foi realizada com o teste t (p=0,05); e as frequências dos tipos de superfície, com o teste do qui-quadrado (p<0,05). Resultados: A Maillefer foi a única régua endodôntica com precisão em todos os comprimentos e orifícios. A Prisma apresentou estatisticamente mais orifícios do tipo S2, quando comparada com outras réguas endodônticas avaliadas (p<0,05). Não houve diferença estatisticamente significativa entre Angelus e Maillefer (p>0,05). Conclusão: A Maillefer apresentou precisão nas porções milimetrada e calibradora. As réguas endodônticas da Angelus não foram precisas em nenhum comprimento da parte milimetrada e não foram precisas na maioria dos orifícios calibradores. A régua endodôntica Prisma mostrou significativamente mais orifícios calibradores com irregularidades na superfície do que Angelus e Maillefer. Destaca-se a necessidade de controle de qualidade e padrões específicos para fabricação das réguas endodônticas (AU).


Objective: The aim was to evaluate the accuracy of the millimeter and calibration portion and evaluate the regularity of the calibrator orifice surfaces of the endodontic rulers. Methods: The millimeter portion of the Angelus, Maillefer, Maquira, Microdont and Prisma rulers was evaluated with an electronic digital caliper. The calibration holes of the Maillefer, Prisma and Angelus were measured with Profile Projector. The surface regularity of calibration holes was evaluated and classified in S1- without irregularities and S2- with irregularities. The accuracy analysis of the millimeter and calibration was performed with T-Test (p=0.05) and the frequencies of the surface types with Chi-square (p<0.05). Results: The Maillefer was the only rulers with accuracy in all lengths and holes. Prisma presented statistically more S2 type holes when compared with other endodontic rulers evaluated (p <0.05). There was no statistically significant difference between Angelus and Maillefer (p> 0.05). Conclusion: The Maillefer presented accuracy in the millimeter and calibration portion. Angelus endodontic rulers were not accurate at any rated length of the millimeter portion and it was not accurate in most calibration holes evaluated. Prisma endodontic ruler showed significantly more calibration holes with irregular surfaces than Angelus and Maillefer. We emphasize the need for quality control and specific standards for endodontic rulers manufacturing (AU).


Subject(s)
Quality Control , Calibration , Electronics , Reference Standards , Methods
5.
Article in English | LILACS-Express | LILACS | ID: biblio-1385799

ABSTRACT

ABSTRACT: This study aimed to compare the trueness and precision of physical models manufactured chairside (intraoral scanner and 3D printed) or by plaster models obtained using impression with alginate or addition silicone. A full- arch stainless steel die was impressed to obtain ten physical models for each group. The models were measured in a stereomicroscope, considering four linear distances. To assess the precision accuracy, an analysis of the measurement variability was carried out, identified by the coefficients of variation and by the Levene's test to compare the groups. To analyze trueness, the data average was subtracted from the database and compared considering alpha as 5 %. Considering precision, the higher dispersion of data occurred in the models obtained with silicone impression. And for trueness, Kruskal Wallis and Dunn tests results did not indicate differences between the groups in the anteroposterior linear distances (p> 0.05). Only in anterior transverse distance obtained through TRIOS (0.31 mm), it presented lower accuracy compared to the models from silicone impression (0.13 mm); however, at transverse posterior distance, the models from silicone impression showed the lowest accuracy (p 0.05). The physical dental models obtained by digital and analog workflows showed acceptable dimensional accuracy expressed by high precision and trueness. There is no difference between the evaluated intraoral scanner systems and the impression materials for the full-arch impression.


RESUMEN: Este estudio tuvo como objetivo comparar la veracidad y precisión de modelos físicos fabricados en la clínica dental (escáner intraoral e impreso en 3D) o por modelos de yeso obtenidos mediante impresión con alginato o silicona de adición. Una matriz de acero inoxidable de arco completo fue impresa para obtener diez modelos físicos para cada grupo. Los modelos se midieron en un estereomicroscopio, considerando cuatro distancias lineales. Se realizó un análisis de la variabilidad de la medida para evaluar la precisión, identificada por los coeficientes de variación y por la prueba de Levene para comparar los grupos. Para analizar la veracidad, el promedio de los datos se restó de la base de datos y se comparó considerando alfa como 5 %. Considerando la precisión, la mayor dispersión de datos ocurrió en los modelos obtenidos con impresión de silicona. Y para la veracidad, los resultados de las pruebas de Kruskal Wallis y Dunn no indicaron diferencias entre los grupos en las distancias lineales anteroposteriores (p> 0,05). Solo en la distancia transversal anterior obtenida mediante TRIOS (0,31 mm) presentó menor precisión en comparación con los modelos de impresión de silicona (0,13 mm); sin embargo, la distancia transversal posterior, los modelos de impresión de silicona mostraron la menor precisión (p 0,05). Los modelos dentales físicos obtenidos mediante flujos de trabajo digitales y analógicos mostraron una precisión dimensional aceptable expresada por alta precisión y veracidad. No se observó diferencia entre los sistemas de escáner intraoral evaluados y los materiales de impresión para la impresión de arco completa.

6.
Dental press j. orthod. (Impr.) ; 26(3): e2119251, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1286213

ABSTRACT

ABSTRACT Objective: This study aimed to evaluate the dimensional stability and maintenance of details of conventional and high stability alginates up to 5-day storage. Methods: Two types of alginates were selected (n=10) for this study, conventional (Hydrogum) and high stability alginates (Hydrogum 5), which were produced with the aid of a cylindrical metal block and a ring-shaped metal mold (Specifications 18, 19, and 25, ANSI/ADA). Ten images were obtained from the molds for the dimensional stability test, which were taken immediately after their production and at each different storage periods (15 min, 24 h, 48 h, 72 h, 96 h, and 120 h) by a digital camera. The specimens were kept hermetically sealed in plastic bags (23°C) and then used to obtain 140 (n=70) dental stone models, used in the detail reproduction test, in which the angular accuracy of three grooves (20 µm, 50 µm, and 75 µm) was observed at each period. The details reproduction accuracy was classified using a predetermined score classification. Measurements of dimensional changes were made in the Corel DRAW X6 program. The data were submitted to the Student's t-test (α?#8197;= 0.05). Results: A statistically significant difference concerning the size of the matrix was observed after 24h for both alginates, and a statistically significant negative linear dimensional change (contraction) was verified after 24 h of storage (1.52% for the high stability alginate, and 1.32% for the conventional alginate). The high stability alginate kept the full details for 72 hours, while the conventional alginate, for 24 h. Both alginates reproduced the 75 µm groove at all storage periods. Conclusion: Impressions made with both alginates presented satisfactory clinical results when the alginates were immediately poured.


RESUMO Objetivo: O presente estudo teve como objetivo avaliar a estabilidade dimensional e manutenção de detalhes de alginatos convencionais e de alta estabilidade por até 5 dias de armazenamento. Métodos: Para esse estudo, foram selecionados dois tipos de alginatos: convencional (Hydrogum) (n = 10) e de alta estabilidade (Hydrogum 5) (n = 10), sendo produzidos com o auxílio de um bloco metálico cilíndrico e um molde metálico em forma de anel (especificações 18, 19 e 25, ANSI/ADA). Para o teste de estabilidade dimensional, dez imagens foram obtidas imediatamente e para cada tempo de armazenamento (15 min, 24, 48, 72, 96 e 120 horas), realizadas por câmera digital. As amostras foram mantidas hermeticamente fechadas em sacos plásticos (23°C). Para o teste de reprodução de detalhes, as amostras foram utilizadas para obter 140 (n = 70 por grupo) modelos de gesso, sendo observada a precisão angular de três sulcos (20 µm, 50 µm e 75 µm) para cada período. A precisão da reprodução de detalhes foi classificada usando uma classificação de pontuação predeterminada. As medições das mudanças dimensionais foram feitas no programa Corel DRAW X6. Os dados foram submetidos ao teste t de Student (α = 0,05). Resultados: Foi observada diferença estatística em relação à matriz após 24h para ambos os alginatos. Uma mudança dimensional linear negativa estatisticamente significativa (contração) foi verificada após 24 h de armazenamento (1,52% para alginato de alta estabilidade; 1,32% para alginato convencional). O alginato de alta estabilidade manteve os detalhes completos por até 72 horas, enquanto o alginato convencional, por 24 horas. Os alginatos reproduziram o sulco de 75 µm para todos os períodos. Conclusão: As impressões feitas com ambos os alginatos devem ser imediatamente vazadas para se ter resultados clínicos satisfatórios.


Subject(s)
Humans , Dental Impression Technique , Dental Impression Materials , Materials Testing , Models, Dental , Alginates
7.
RFO UPF ; 25(3): 443-451, 20201231. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1357828

ABSTRACT

Objetivo: este estudo avaliou a acurácia e confiabilidadedas medidas lineares em exames detomografia computadorizada de feixe cônico(TCFC), em dois softwares, utilizando diferentesvoxels e variando o posicionamento da mandíbula.Material e Métodos: 10 imagens de TCFC demandíbulas humanas com 25 pontos foram obtidas,usando diferentes protocolos de aquisição(0.250, 0.300, 0.400-mm voxels) e orientações damandíbula (centralizada, rotacionada 10° lateralmentepara direita e esquerda, inclinada 10° para cima e para baixo); 14 medidas foram realizadasnas reconstruções multiplanares nos softwares XoranCate OsiriX. Os achados foram comparadoscom as medidas físicas através de um paquímetrodigital. O teste ANOVA e o coeficiente de correlaçãoforam utilizados com p < 0,05. Resultados:não houve diferença estatisticamente significantequando as medidas foram comparadas em aquisiçõescom diferentes tamanhos de voxels emambos os softwares. A posição da mandíbula nãoinfluenciou nas medidas. Nenhuma diferença foiencontrada quando os valores foram comparadosentre os softwares e o paquímetro digital. Conclusão:as medidas lineares em ambos os softwaresforam confiáveis e acurados comparados a mensuraçãofísica em todos os protocolos. A acuráciae a confiabilidade das mensurações não influenciaramde acordo com as variações de posicionamentoda mandíbula.(AU)


Objective: this study evaluated the accuracy and reliability of linear measurements on cone beam CT (CBCT) scans in two software programs, using different voxels and varying mandible positioning. Material and methods: CBCT images of 10 human mandibles with 25 markers were obtained using different acquisition protocols (0.250, 0.300, 0.400-mm voxels) and mandible orientations (centered, rotated 10° laterally to right and left, tilted 10 up and down); fourteen measurements were carried out on the multiplanar reconstructions in XoranCat and OsiriX Lite software programs. The findings were compared to physical measurements using a digital caliper. ANOVA and correlation coefficient tests were used, at α = 0.05. Results: there was no statistically significant difference when the measurements were compared in acquisitions with different voxel sizes analysed in both software programs. Mandibular positioning changes did not influence the measurements. No differences were found when the values were compared between the software programs and the digital caliper. Conclusion: linear measurements in both programs were reliable and accurate compared with physical measurements when using all acquisition protocols. The accuracy and reliability of the measurements were not influenced by variations in the mandible positioning.(AU)


Subject(s)
Humans , Software/standards , Cone-Beam Computed Tomography/standards , Dimensional Measurement Accuracy , Mandible/diagnostic imaging , Reference Values , Reproducibility of Results , Analysis of Variance , Cone-Beam Computed Tomography/methods
8.
Rev. latinoam. enferm. (Online) ; 28: e3299, 2020. tab, graf
Article in English | BDENF, LILACS | ID: biblio-1126959

ABSTRACT

Objective: to evaluate the use of the 2D-FlexRuler as a facilitating tool for the early calculation of the predictive scar factor of chronic wounds. Method: a descriptive study with a quantitative, experimental, longitudinal and prospective approach. The sample consisted of 22 outpatients. 32 chronic wounds were analyzed. The wound edges were identified and drawn on the 2D-FlexRuler. The calculations of the areas of chronic wounds were obtained by manual, traditional methods, by software and Matlab algorithm. These areas were compared with each other to determine the efficiency of the proposed ruler in relation to traditional methods. Results: the calculation of the wound area by the traditional method and Kundin's coefficient show average errors greater than 40%. The manual estimation of the area with the 2D-FlexRuler is more accurate in relation to traditional measurement methods, which were considered quantitatively disqualified. When compared with the reference method, for example, the Klonk software, the data obtained by 2D-FlexRuler resulted in an error of less than 1.0%. Conclusion: the 2D-FlexRuler is a reliable metric platform for obtaining the anatomical limits of chronic wounds. It facilitated the calculation of the wound area under monitoring and allowed to obtain the scar predictive factor of chronic wounds with precocity in two weeks.


Objetivo: avaliar o uso da régua 2D-FlexRuler como ferramenta facilitadora para o cálculo precoce do fator preditivo cicatricial de feridas crônicas. Método: estudo descritivo com abordagem quantitativa, experimental, longitudinal e prospectiva. A amostra foi de 22 pacientes ambulatoriais. Foram analisadas 32 feridas crônicas. As bordas das feridas foram identificadas e desenhadas na 2D-FlexRuler. Os cálculos das áreas das feridas crônicas foram obtidos pelos métodos manuais, tradicionais, por softwares e algoritmo Matlab. Essas áreas foram comparadas entre si para determinar a eficiência da régua proposta em relação aos métodos tradicionais. Resultados: o cálculo da área da ferida pelo método tradicional e coeficiente de Kundin demonstram erros médios maiores do que 40%. A estimativa manual da área com a 2D-FlexRuler é mais exata em relação aos métodos tradicionais de medição, os quais foram considerados quantitativamente desqualificados. Quando comparada com o método de referência, i.e., o software Klonk, os dados obtidos pela 2D-FlexRuler resultaram em um erro menor que 1,0%. Conclusão: a régua 2D-FlexRuler é uma plataforma métrica confiável para a obtenção dos limites anatômicos de feridas crônicas. Facilitou o cálculo da área da ferida sob monitoramento e permitiu obter o fator preditivo cicatricial de feridas crônicas com precocidade em duas semanas.


Objetivo: evaluar el uso de la regla 2D-FlexRuler como herramienta facilitadora para el cálculo temprano del factor predictivo de cicatrices en heridas crónicas. Método: estudio descriptivo con enfoque cuantitativo, experimental, longitudinal y prospectivo. La muestra consistió en 22 pacientes ambulatorios. Se analizaron 32 heridas crónicas. Los bordes de la herida fueron identificados y dibujados en 2D-FlexRuler. Los cálculos de las áreas de heridas crónicas se obtuvieron por métodos manuales, tradicionales, por software y algoritmo Matlab. Estas áreas se compararon entre sí para determinar la eficiencia de la regla propuesta en relación con los métodos tradicionales. Resultados: el cálculo del área de la herida por el método tradicional y el coeficiente de Kundin muestran errores promedio superiores al 40%. La estimación manual del área con 2D-FlexRuler es más precisa en relación con los métodos de medición tradicionales, que se consideraron descalificados cuantitativamente. Al ser comparados con el método de referencia, es decir, el software Klonk, los datos obtenidos por 2D-FlexRuler arrojaron un error de menos del 1,0%. Conclusión: la regla 2D-FlexRuler es una plataforma métrica confiable para obtener los límites anatómicos de las heridas crónicas. Facilitó el cálculo del área de la herida bajo monitoreo y permitió obtener el factor predictivo de cicatriz de heridas crónicas con precocidad en dos semanas.


Subject(s)
Weights and Measures , Wound Healing , Wounds and Injuries , Software , Cicatrix , Dimensional Measurement Accuracy , Surgical Wound , Metronidazole
9.
Pesqui. bras. odontopediatria clín. integr ; 20: e5108, 2020. tab
Article in English | BBO, LILACS | ID: biblio-1135481

ABSTRACT

Abstract Objective: To verify the concordance in the evaluation of the apical limit of obturation (ALO) in filled root canals of primary teeth between digital and visual methods. Material and Methods: Twenty periapical radiographs of endodontically treated primary teeth were digitalized and evaluated by an endodontics specialist (E1), a PhD pediatric dentist (E2), and a MSc general dentist (E3). Calibrated evaluators (Kappa = 1.00) analysed the images in a light-isolated environment two times (D1 and D2) with a one-week interval between evaluations. ALO scores were categorized as overfilled, flush-filled and underfilled. Results: The intra-rater reliability between methods was 0.82 (D1) and 0.75 (D2) for E1, 0.93 (D1 and D2) for E2, and 0.94 (D1 and D2) for E3. Inter-rater reliability ranged from 0.71 (E1 × E3) and 1.00 (E1 × E2) for the visual method to 0.76 (E1 × E3) and 0.88 (E1 × E2) for the digital method. Spearman correlation coefficients showed a similar ranking among the evaluators. There was greater disagreement among the underfilled and ideal scores. For all evaluators, the digital method favoured the identification of the ideal score. Conclusion: Both methods are suitable for the determination of the ALO of filled primary teeth and can be used in clinical practice.


Subject(s)
Humans , Root Canal Obturation , Root Canal Therapy/instrumentation , Tooth, Deciduous , Pilot Projects , Dental Pulp Cavity , Dimensional Measurement Accuracy , Brazil , Radiography, Dental/instrumentation , Statistics, Nonparametric , Dentists
10.
Imaging Science in Dentistry ; : 37-43, 2020.
Article in English | WPRIM | ID: wpr-811165

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the accuracy of linear measurements in the horizontal and vertical dimensions based on object position and slice inclination in cone-beam computed tomography (CBCT) images.MATERIALS AND METHODS: Ten dry sheep hemi-mandibles, each with 4 sites (incisor, canine, premolar, and molar), were evaluated when either centrally or peripherally positioned within the field of view (FOV) with the image slices subjected to either oblique or orthogonal inclinations. Four types of images were created of each region: central/cross-sectional, central/coronal, peripheral/cross-sectional, and peripheral/coronal. The horizontal and vertical dimensions were measured for each region of each image type. Direct measurements of each region were obtained using a digital caliper in both horizontal and vertical dimensions. CBCT and direct measurements were compared using the Bland-Altman plot method. P values <0.05 were considered to indicate statistical significance.RESULTS: The buccolingual dimension of the incisor and premolar areas and the height of the incisor, canine, and molar areas showed statistically significant differences on the peripheral/coronal images compared to the direct measurements (P<0.05). Molar area height in the central/coronal slices also differed significantly from the direct measurements (P<0.05). Cross-sectional images of either the central or peripheral position had no marked difference from the gold-standard values, indicating sufficient accuracy.CONCLUSION: Peripheral object positioning within the FOV in combination with applying an orthogonal inclination to the slices resulted in significant inaccuracies in the horizontal and vertical measurements. The most undesirable effect was observed in the molar area and the vertical dimension.

11.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 41-46, 2020.
Article in Chinese | WPRIM | ID: wpr-781200

ABSTRACT

Objective@#To compare the measurement accuracy of two⁃dimensional (2D) photography and three⁃di⁃mensional (3D) photography in the analysis of the asymmetric appearance of children with cleft lip and palate and the influence of the severity of asymmetric deformity on the accuracy of facial measurement to guide clinical measurement work@* Methods@#Children with unilateral cleft lip were enrolled in this prospective study. Seven parameters⁃⁃the devia⁃tion of the pronasale, subnasale, and labrale superius, as well as the cleft/noncleft ratio of the width of nostrils, length and height of lateral lips and height of columella⁃were measured with Vernier calipers as the gold standard. Traditional 2D photography and 3D stereophotogrammetry photos were taken and measured. The extent of cleft malformation is indi⁃cated by the ratio of the cleft side to the noncleft side. The error size is represented by the ratio difference between two⁃dimensional photography or stereophotogrammetry with the ratio of the gold standard@* Results@#Thirteen patients were eventually recruited. The measurement results of the ratio of lateral lip height by 2D photography tended to be larger (P=0.019), and the measurement results of the ratio of columella height tended to be smaller (P=0.008). The measure⁃ment results of the deviation of the subnasale by stereophotogrammetry tended to be smaller (P=0.003). The pronasale deviation (P=0.022) with two⁃dimensional photography, the deviation of the labrale superius (P=0.025) and the ratio of lateral lip length (P=0.036) with stereophotogrammetry had a significant negative correlation with the extent of cleft malformation@* Conclusion@#Both two⁃dimensional photography and stereophotogrammetry have errors and biases that underexaggerate or overexaggerate the extent of cleft malformation, and some errors may increase with the decrease in the extent of cleft malformation. When applying two⁃dimensional and three⁃dimensional photography to analyze cleft lip and palate deformities, these biases should be considered to evaluate the face more objectively

12.
Arq. gastroenterol ; 56(3): 294-299, July-Sept. 2019. tab
Article in English | LILACS | ID: biblio-1038710

ABSTRACT

ABSTRACT BACKGROUND: During weight gain, most of the excess adipose tissue accumulates in the trunk. This alters the body shape and makes collection of anthropometric measurements, especially waist circumference (WC), difficult. OBJECTIVE: To evaluate the sensitivity and applicability of additional abdominal measurements in order to assess body composition of obese women. METHODS: A total of 30 women between 20 and 50 years of age and BMI above 30 kg/m² were assessed. Three WC measurements, were performed: at the umbilical scar designated as WC1 and at 8 and 16 cm above the umbilical scar, designated as WC2, and WC3 respectively. The correlation (r) between these anthropometric measurements and their sum was assessed against the parameters fat mass (FM), free fat mass (FFM), body fat percentage (%BF), and trunk fat percentage (%TF), obtained by total and trunk segmental bioelectric impedance analysis (BIA) as well as by the golden standard total and trunk dual energy X-ray absorptiometry (DXA). RESULTS: The measurements WC1, WC2, WC3, and their sum correlated strongly and moderately with the parameters FM, FFM, and %BF in total BIA and in both total DXA and trunk DXA. CONCLUSION: The results demonstrated a robust correlation between the sum of the three WC measurements and total and trunk DXA in obese women suggesting that such measurements may be a good indicator of body and trunk fat in women, actually superior to BIA results. The use of these three measurements may be an alternative for the assessment of body and trunk fat, in those cases in which the body shape due to adipose tissue trunk accumulation makes accurate classical measurement (WC1) difficult.


RESUMO CONTEXTO: O acúmulo de tecido adiposo excessivo no ganho de peso se dá em maior proporção no segmento do tronco, leva à alteração dos formatos corporais dificultando a tomada de medidas antropométricas, em especial a circunferência abdominal (CA). OBJETIVO: Avaliar a sensibilidade de medidas adicionais na região abdominal, considerando cada medida individualmente e sua somatória, e a aplicabilidade dessas medidas na avaliação da composição corporal de mulheres obesas. MÉTODOS: Foram avaliadas 30 mulheres com idade entre 20 e 50 anos e IMC acima de 30 kg/m² com a realização de três medidas de CA denominadas: CA1 padronizada na cicatriz umbilical, CA2 a 8 cm acima da cicatriz umbilical e CA3 a 16 cm acima da cicatriz umbilical. Foi avaliada a correlação (r) destas medidas antropométricas e de sua somatória com os parâmetros massa gorda (MG), massa livre de gordura (MLG), porcentagem de gordura corporal (%GC) e do tronco (%GT) obtidos por impedância bioelétrica (BIA) total e segmentar do tronco e por absorciometria de raios-X de dupla energia (DXA) total e do tronco, como padrão ouro. RESULTADOS: As medidas CA1, CA2, CA3 e a somatória das três tiveram correlação forte e moderada com os parâmetros MG, MLG e %GC tanto para BIA total como para DXA total e DXA do tronco. CONCLUSÃO: Os resultados deste estudo mostram forte correlação entre a soma das medidas de três pontos no abdome com DXA de tronco e total, em mulheres obesas, sugerindo serem estas medidas, um bom indicador de gordura corporal e de gordura da região do tronco, superior aos resultados obtidos por BIA. O uso dessas três medidas pode ser um indicador alternativo de avaliação da gordura corporal e de tronco, nos casos em que o formato corporal de acúmulo de gordura na região do tronco, dificultar a acurácia da medida clássica (CA1).


Subject(s)
Humans , Female , Adult , Young Adult , Body Composition/physiology , Abdominal Fat/metabolism , Waist Circumference/physiology , Obesity/metabolism , Body Weight , Body Mass Index , Electric Impedance , Middle Aged
13.
Pesqui. bras. odontopediatria clín. integr ; 19(1): 4137, 01 Fevereiro 2019. tab
Article in English | LILACS, BBO | ID: biblio-998205

ABSTRACT

Objective: To evaluate the dimensional changes in three types of alginate following three different delay times after casting. Material and Methods: In this laboratory study, a maxillary arch-shaped stainless steel model was prepared and three pins with similar and determined diameters and heights were placed (one at mid-line and two on the underside of the model) as reference points to compare the dimensional stability of the three types of alginates. A special metal tray was made from the main model. The main moldel was imprisoned by the metal tray, and these were kept for a specific time in a humid environment. Gypsum Type 4 was poured over the impression to obtain 90 gypsum casts for three types of alginate. The dimensions of casts obtained from each alginate were compared in two lateral and anterior-posterior dimensions, they were compared with each other, and the alginates were also compared to the main model. Results: At a time interval of 15 minutes, the dimensional accuracy of the casts obtained from the three types of alginates, with the main model in both anterior-posterior and transverse dimensions was not significantly different (p<0.05); but there was a significant difference at 60 minutes and 24 hours in both dimensions (p<0.05). Although there was no significant difference between the alginates in both dimensions and all three studied time periods, the least difference with the main model was related to Zhermack and the highest difference was related to Golchai alginates. Pairwise comparisons showed that none of the samples had a significant difference in terms of dimensions. Conclusion: The dimensional stability of alginate was a time-dependent type of alginate and had no significant effect on the dimensional accuracy of casts.


Subject(s)
Dental Impression Technique , Models, Dental , Alginates , Dimensional Measurement Accuracy , Analysis of Variance , Dental Impression Materials , Iran
14.
Odontología (Ecuad.) ; 21(2): 39-50, 2019.
Article in Spanish | LILACS | ID: biblio-1050139

ABSTRACT

Objetivo: El propósito de este estudio fue evaluar el uso de un jig de verificación para corregir la posición de los implantes dentales en un modelo impreso en 3D y comparar su precisión con los modelos dentales obte-nidos por impresión convencional. Materiales y Métodos: Se instalaron tres implantes dentales en un modelo maxilar dentado parcial y se obtuvieron moldes dentales (n = 10) mediante impresiones convencionales y digi-tales. Se usó una plantilla de verificación para determinar la posición del implante en el modelo impreso en 3D y su precisión se comparó con el molde convencional. Resultados: Los datos se analizaron mediante ANOVA y prueba post hoc a un nivel de significancia de p ≤ 0.05. Se encontró un error de medición estadísticamente mayor (p≤ 0.05) para los modelos impresos en 3D en comparación con los modelos convencionales, con una diferencia media de 47 µm. Conclusión: El uso de un jig de verificación para colocar implantes dentales en un modelo impreso en 3D mostró mayores discrepancias en comparación con las impresiones convencionales.


Objective: The purpose of this study was to assess the use of a verification jig to correct the position of den-tal implants in a 3D printed model and to compare its accuracy with dental casts obtained by conventional impression. Materials and Methods: Three dental implants were installed in a partial dentate maxillary model and dental casts (n=10) were obtained by conventional and digital impressions. A verification jig was used to determine the implant position into the 3D printed model and its accuracy was compared with conventional cast. Results: Data were analyzed by within ANOVA and post hoc test at a significance level of p ≤ 0.05. A statistically higher measurement error (p≤ 0.05) was found for 3D printed models in comparison with conven-tional models, with a mean difference of 47µm. Conclusion: The use of verification jig for positioning dental implants in a 3D printed model


Objetivo: O objetivo deste estudo foi avaliar o uso de um jig de verificação para corrigir a posição dos implan-tes dentários em um modelo impresso em 3D, e comparar sua precisão com os modelos dentários obtidos pela impressão convencional. Materiais e Métodos: Três implantes dentários foram instalados em um modelo maxilar parcialmente dentado e os moldes dentários (n = 10) foram obtidos por impressões convencionais e digitais. Um modelo de verificação foi usado para determinar a posição do implante no modelo impresso em 3D e sua precisão foi comparada com o molde convencional. Resultados: Os dados foram analisados por ANOVA e teste post hoc com nível de significância de p ≤ 0,05. Foi encontrado um erro de medição estatistica-mente maior (p≤ 0,05) para os modelos impressos em 3D em comparação aos modelos convencionais, com uma diferença média de 47 µm. Conclusão: O uso de um jig de verificação para colocação de implantes dentários em um modelo impresso em 3D mostrou maiores discrepâncias em relação às impressões conven-cionais.


Subject(s)
Dental Implants , Dental Prosthesis , Printing, Three-Dimensional , Analysis of Variance , Dimensional Measurement Accuracy
15.
Braz. j. oral sci ; 18: e191692, jan.-dez. 2019. ilus
Article in English | LILACS, BBO | ID: biblio-1095302

ABSTRACT

Aim: This study compared impression techniques and double pouring by means of cast's accuracy. Methods: For each patient (n=10), impressions from right maxillary canine to first molar were made with acrylic resin trays and vinyl-polysiloxane using one single-step, and four two-steps techniques: relief with poly(vinyl chloride) film; tungsten-carbide bur/scalpel blade; small movements of the tray; non-relief. Total visible buccal surface area of crowns was measured three times using photographs from patients (Baseline) and casts. Mean area values (mm2) between Baseline and casts differences were analyzed by two-way repeated-measures ANOVA (α=.05; 1-ß=85%). Results: No significant differences were observed for Impression Techniques (P=.525), Double Pouring (P=.281), and their interaction (P=.809). Conclusion: All impression techniques and double pouring produced casts with similar accuracy


Subject(s)
Humans , Male , Female , Dental Impression Technique , Photography, Dental , Dental Impression Materials , Dimensional Measurement Accuracy
16.
Rev. odontol. UNESP (Online) ; 48: e20190098, 2019. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1099193

ABSTRACT

Resumo Introdução Recentemente, vêm surgindo no mercado alguns alginatos de armazenamento prolongado. Não há, no entanto, um consenso na literatura a respeito da estabilidade dimensional destes materiais durante este armazenamento Objetivo Avaliar, por meio de método prático experimental, a estabilidade dimensional de um alginato de armazenamento tardio. Material e método O material de moldagem utilizado foi o alginato Hydrogum 5 (Zhermack). Uma matriz metálica cilíndrica foi utilizada para a realização das moldagens, com 38 mm de diâmetro externo, 30 mm de diâmetro interno e cuja superfície superior apresenta três linhas paralelas entre si com 25 mm de comprimento e 20, 50 e 75 µm de largura. Após o tempo de geleificação do material de moldagem, 16 moldes foram colocados em um umidificador e essas amostras foram fotografadas utilizando-se uma câmera digital (Canon EOS Rebel 3Ti, Canon) associada a um software para análise das imagens obtidas (ImageJ 1.52a, U.S. National Institutes of Health; DI). A calibragem da régua foi 10 cm e, posteriormente, três linhas foram medidas três vezes, para se obter uma média dos comprimentos das linhas. As amostras foram fotografadas nos seguintes intervalos: imediatamente, 24, 48, 72, 96 e 120 horas. Resultado Os dados mostraram diferenças estatisticamente significantes para o fator tempo quando comparada a leitura imediata com os demais períodos de tempo de leitura (p<0,001) e quando comparada a leitura após 24 h de armazenagem com os demais períodos de tempo (p<0,001). Não houve diferença estatística (p>0,05) quando os tempos de armazenamento de 48 h, 72 h, 96 h e 120 h foram comparados entre si. Todos os valores encontravam-se dentro dos valores preconizados pela ISO 21563:2013. Conclusão Os moldes dos alginatos testados podem ser armazenados por até cinco dias em 100% de umidade relativa.


Abstract Introduction Recently, some extended-pour alginate impression materials have been placed in the market. However, there is no consensus in the literature regarding the dimensional stability of these materials during these storage. Objective To evaluate, through the experimental model, the durability and velocity with respect to dimensional alteration, analyzing the material and detecting distortions. Material and method The material for molding in this test was alginate (Hydrogum 5, Zhermack). A cylindrical metallic matrix was used to make the moldings with: 38 mm of external diameter, 30 mm of internal diameter and superior of the upper series of the card 3d transport lines with each 25 mm in length and 20, 50 and 75μm in width. After the time of jellification / polymerization of the molding material, 16 molds were inserted in a doser and were photographed with a digital camera (Canon EOS Rebel 3Ti, Canon) associated with a software for analysis of sacred images (ImageJ 1.52a, US National Institutes of Health, DI). The calibration of the ruler was performed in 10 cm and then in 3 lines were means 3 (three) times to obtain a mean of the lengths of the lines. The photographs were taken at the following intervals: immediately, 24, 48, 72, 96 and 120 hours after being cast. Result The data were found when compared with the other parts of the reading time (p <0.001) and when compared to the execution after 24 hours of locomotion with the other parts of the time (p <0.001). The rest time of 48 hours, 72 hours, 96 hours and 120 hours were compared to each other. Conclusion The molds of the tested alginates can be stored for 5 days in 100% relative sauce.


Subject(s)
Dental Impression Materials/standards , Alginates , Dimensional Measurement Accuracy
17.
Imaging Science in Dentistry ; : 159-169, 2019.
Article in English | WPRIM | ID: wpr-763989

ABSTRACT

PURPOSE: Cone-beam computed tomography (CBCT) is widely used for 3-dimensional assessments of cranio-maxillofacial relationships, especially in patients undergoing orthognathic surgery. We have introduced, for reference in CBCT cephalometry, an anatomical mid-sagittal plane (MSP) identified by the nasion, the midpoint between the posterior clinoid processes of the sella turcica, and the basion. The MSP is an updated version of the median plane previously used at our institution for 2D posterior-anterior cephalometry. This study was conducted to test the accuracy of the CBCT measures compared to those obtained using standard posterior-anterior cephalometry. MATERIALS AND METHODS: Two operators measured the inter-zygomatic distance on 15 CBCT scans using the MSP as a reference plane, and the CBCT measurements were compared with measurements made on patients' posterior-anterior cephalograms. The statistical analysis evaluated the absolute and percentage differences between the 3D and 2D measurements. RESULTS: As demonstrated by the absolute mean difference (roughly 1 mm) and the percentage difference (less than 3%), the MSP showed good accuracy on CBCT compared to the 2D plane, especially for measurements of the left side. However, the CBCT measurements showed a high standard deviation, indicating major variability and low precision. CONCLUSION: The anatomical MSP can be used as a reliable reference plane for transverse measurements in 3D cephalometry in cases of symmetrical or asymmetrical malocclusion. In patients who suffer from distortions of the skull base, the identification of landmarks might be difficult and the MSP could be unreliable. Becoming familiar with the relevant software could reduce errors and improve reliability.


Subject(s)
Humans , Cephalometry , Cone-Beam Computed Tomography , Dimensional Measurement Accuracy , Malocclusion , Orthognathic Surgery , Sella Turcica , Skull Base
18.
Prosthes. Esthet. Sci ; 7(26): 64-70, 20180100. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-885147

ABSTRACT

O objetivo deste estudo foi mensurar e comparar a precisão dimensional de modelos de gesso confeccionados por meio de moldagem de impressão única (material pesado/fluído de uma única vez) com quatro diferentes marcas comerciais de silicone polimerizados por reação de adição (Express XT®, Futura®, Aquasil® e Virtual®). Inicialmente, foi confeccionado um modelo acrílico mestre, o qual possuía três pilares metálicos paralelos entre si e equidistantes 50 mm um do outro. Para obtenção dos moldes foram utilizadas cinco moldeiras individuais em acrílico, cujas faces externas adaptavam-se perfeitamente na base do modelo padrão, promovendo o "stop" de inserção da moldeira. Após o procedimento de moldagem e confecção dos modelos experimentais, foram medidas as distâncias entre os três cilindros e o diâmetro de cada cilindro. Essas medições foram feitas por três vezes em um mesmo ponto e, destas, criou-se uma média obtendo os resultados finais. Os valores das distâncias foram analisados estatisticamente por meio de uma análise bifatorial, e as médias comparadas pelo teste de Tukey (5%). Os dados demostraram que todas as marcas analisadas apresentaram alteração dimensional e diferiram entre si quando comparadas.


The objective of this study was to measure and compare the dimensional accuracy of plaster models made by only impression molding (heavy material/fluid at one time) of four different brands of polymerized silicone through addition reaction (Express XT®, Futura ®, Aquasil® and Virtual®). Initially, a master acrylic model was manufactured, which had three parallel metal pillars and equidistant 50 mm from each other. To obtain the impressions, we used five individual acrylic trays, whose external faces perfectly adapted to the standard model base, thus promoting the "stop" of molding insertion. Following the molding procedure and the experimental models manufacturing, distances between the three cylinders and the diameter of each cylinder were measured. These measurements were made three times at the same point, and from these average results were obtained. The distance values were statistically analyzed using a two-factor analysis and the means compared by Tukey test (5%). The data demonstrated that all the analyzed brands presented dimensional changes and differed from each other when compared.


Subject(s)
Humans , Calcium Sulfate , Dental Impression Materials , Dimensional Measurement Accuracy , Silicone Elastomers , Silicones/chemistry
19.
Imaging Science in Dentistry ; : 111-119, 2018.
Article in English | WPRIM | ID: wpr-740372

ABSTRACT

PURPOSE: This study was conducted to evaluate the accuracy of linear measurements of 3-dimensional (3D) images generated by cone-beam computed tomography (CBCT) and facial scanning systems, and to assess the effect of scanning parameters, such as CBCT exposure settings, on image quality. MATERIALS AND METHODS: CBCT and facial scanning images of an anthropomorphic phantom showing 13 soft-tissue anatomical landmarks were used in the study. The distances between the anatomical landmarks on the phantom were measured to obtain a reference for evaluating the accuracy of the 3D facial soft-tissue images. The distances between the 3D image landmarks were measured using a 3D distance measurement tool. The effect of scanning parameters on CBCT image quality was evaluated by visually comparing images acquired under different exposure conditions, but at a constant threshold. RESULTS: Comparison of the repeated direct phantom and image-based measurements revealed good reproducibility. There were no significant differences between the direct phantom and image-based measurements of the CBCT surface volume-rendered images. Five of the 15 measurements of the 3D facial scans were found to be significantly different from their corresponding direct phantom measurements (P < .05). The quality of the CBCT surface volume-rendered images acquired at a constant threshold varied across different exposure conditions. CONCLUSION: These results proved that existing 3D imaging techniques were satisfactorily accurate for clinical applications, and that optimizing the variables that affected image quality, such as the exposure parameters, was critical for image acquisition.


Subject(s)
Anthropometry , Cone-Beam Computed Tomography , Dimensional Measurement Accuracy , Imaging, Three-Dimensional
20.
Braz. dent. sci ; 21(3): 320-327, 2018. ilus, tab
Article in English | LILACS, BBO | ID: biblio-911567

ABSTRACT

Objective: This in vitro study aimed to determine and compare the dimensional accuracy of open and closed-tray impression techniques for implantsupported prosthesis. Material and Methods: On a edentulous master model, four external hexagonal implants were parallelly installed and associated with four multi unit coping transfers and four multi unit rotational caps. A master superstructure was constructed and splinted all implants (control group). Five customized trays were constructed to perform ten open (n=5) and closed-tray (n=5) impressions. The obtained models were submitted to the dimensional analysis on three points in the center of the labial face of each implant (A, B, C, and D) with the aid of Stereoscopic Magnifying Glass with x60 magnification. The vertical misfit between the metallic structure and the implant analogues was measured on each point. The obtained results were submitted to Dixon's normality test and KruskalWallis test for independent samples p < 0.05) with the aid of Bioestat 5.0 software. Results: The means and standard deviation were: open tray technique ­ 24.6474 ± 14.8883 µm; closed-tray technique ­ 26.2257 ± 9.7421 µm; and control group 22.445 ± 7.7106 µm. Conclusion: The accuracy of open and closed-tray impression techniques showed no statistically significant differences and both techniques were effective for implant transfer. (AU)


Objetivos: O presente estudo in vitro objetiva determinar e comparar a precisão dimensional das técnicas de transferência de implantes direta e indireta para próteses implantossuportadas. Material e Métodos: a partir de um modelo mestre mandibular desdentado, foram instalados paralelamente quatro implantes hexágonos externos associados a quatro componentes multi unit e quatro capas multi unit rotacionais. Confeccionou-se uma infraestrutura mestre metálica unindo todos os elementos, considerando o conjunto como grupo controle (GC). Ao todo, fabricaram-se cinco moldeiras individuais para realizar 10 moldagens mediante as técnicas direta e indireta (n= 5), sendo os modelos obtidos submetidos à análise dimensional e estatística. Com uma lupa estereoscópica binocular com ampliação de 60 x, estabeleceram-se três pontos no centro da face vestibular de cada um dos implantes (A, B, C e D) por amostra. Em cada ponto, mensurou-se o desajuste vertical entre a estrutura metálica e os análogos. Os resultados obtidos foram submetidos ao teste de normalidade de Dixon e teste de Kruskal- Wallis para amostras independentes (p< 0,05) com o auxílio do software Bioestat 5.0. Resultados: médias aritméticas e desvio padrão identificados no grupo moldagem direta (24,6474 ± 14,8883 µm) e moldagem indireta (26,2257 ± 9,7421 µm) em comparação com o modelo mestre (22,445 ± 7,7106 µm). Conclusão: Pôde-se concluir que não houve diferenças estatísticas significativas entre as técnicas na precisão da transferência de implantes, sendo ambas igualmente eficientes. (AU)


Subject(s)
Dental Implants , Dental Impression Technique , Dental Prosthesis, Implant-Supported , Dimensional Measurement Accuracy , Investigative Techniques , Oral Surgical Procedures , Technology, Dental
SELECTION OF CITATIONS
SEARCH DETAIL